New magnetic stirrer with heating and ceramic heating plate which offers excellent chemical resistance.
Number of stirring positions | 1 |
Stirring quantity max. per stirring position (H2O) | 10 l |
Stirring quantity max. (H2O) | 10 l |
Motor rating input | 15 W |
Motor rating output | 1.5 W |
Speed display | scale |
Speed range | 100 – 1500 rpm |
Stirring bar length max. | 80 mm |
Heat output | 1000 W |
Heating rate (1 l H2O in H15) | 5 K/min |
Heating temperature range | 50 – 500 °C |
Heat control | LED |
Heat control accuracy | 10 ±K |
Speed control | scale 0 – 6 |
Fixed safety circuit | 550 °C |
Connection for ext. temperature sensor | ETS-D5 |
Control accuracy with sensor | 3 ±K |
Temperature constancy in medium | 3 ±K |
Set-up plate material | ceramic |
Set-up plate dimensions | 180 x 180 mm |
Dimensions (W x H x D) | 220 x 105 x 330 mm |
Weight | 5 kg |
Permissible ambient temperature | 5 – 40 °C |
Permissible relative moisture | 80 % |
Protection class according to DIN EN 60529 | IP 21 |
Voltage | 230 / 120 / 100 V |
Frequency | 50/60 Hz |
Power input | 1020 W |
Conductivty Meter-HC30102
The Professional Conductivity Meter HC3010 is a highly sophisticated conductivity meter with the ability to automatically display and convert readings into different units of µSiemen (µS), mSiemen (mS), TDS in ppm and Salinity in ppt. The meter is versatile and able to preset at different conversion factors. Users can select to display in Conductivity or TDS. Its 99 data memory coupled with a real time clock is able to record readings with date and time. For QC control, data can be analyzed to display maximum and minimum readings over all saved data. It is most suitable for on-site field testing. The meter comes complete in a hard carrying case with a set of calibration fluids for on the spot calibration.
Features
Model: | HC3010 Professional Conductivity meter | |||||
Auto Range: | 0 – 19.9µS | – 199.9µS | -1999 µS | – 19.99mS | – 199.9 mS | 0 – 50°C |
0 – 19.99ppm | – 199.9ppm | -1999ppm | – 19.99ppt | – 199.9ppt | 0 – 80°C | |
Resolution: | 0.1 µS | 0.1 µS | 1 µS | 0.01 mS | 0.1 mS | 0.1°C |
0.01 ppm | 0.1 ppm | 1 ppm | 0.01 ppt | 0.1 ppt | ||
Accuracy : | ± 1% F.S. + 1digit | ±0.6°C/± 1°C | ||||
Calibration: | 5 point over full range, 1 point over salinity range in NaCl | |||||
TDS factor: | Adjustable 0.4 to 1.00 | |||||
Cell constant: | Selectable 0.1, 1.0, 10.0 | |||||
ATC | Automatic 0 – 80°C | |||||
Battery type: | 4 x 1.5V AAA size battery or DC9V adaptor (optional item) | |||||
Size: | 195 x 40 x 36mm | |||||
Weight: | 150gm |
HI4321 Conductivity / TDS Benchtop Meter
Range | EC | 0.000 to 9.999 µS/cm; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000 mS/cm (actual EC) |
Resistivity | 1.0 to 99.9 Ohms x cm; 100 to 999 Ohms x cm; 1.00 to 9.99 kOhms x cm; 10.0 to 99.9 kOhms x cm; 100 to 999 kOhms x cm; 1.00 to 9.99 MOhms x cm; 10.0 to 100.0 MOhms x cm | |
TDS | 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt actual TDS (with 1.00 factor) | |
Salinity | practical scale: 0.00 to 42.00 psu; natural sea water scale: 0.00 to 80.00 ppt; percent scale: 0.0 to 400.0% | |
Temperature | -20.0 to 120°C; -4.0 to 248.0°F; 253.15 to 393.15K | |
Resolution | EC | 0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
Resistivity | 0.1 Ohms x cm; 1 Ohms x cm; 0.01 kOhms x cm; 0.1 kOhms x cm; 1 kOhms x cm; 0.01 MOhms x cm; 0.1 MOhms x cm | |
TDS | 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt | |
Salinity | 0.01 for practical scale/natural sea water scale; 0.1% for percent scale | |
Temperature | 0.1°C; 0.1°F; 0.1K | |
Accuracy | EC | ±1% of reading (±0.01 µS/cm) |
Resistivity | ±2% of reading (±1 Ohm x cm) | |
TDS | ±1% of reading (±0.01 ppm) | |
Salinity | ±1% of reading | |
Temperature | ±0.2°C; ±0.4°F; ±0.2K (excluding probe error) | |
Calibration | EC | auto standard recognition, custom calibration solution/four point calibration |
Salinity | percent scale—one point (with HI 7037 standard) | |
Temperature | three points | |
Temperature Compensation |
linear and non-linear (natural water) | |
TDS Factor | 0.40 to 1.00 | |
EC Probe | HI 76312 platinum, four ring conductivity/TDS probe with internal temperature sensor and 1 m (3.3’) cable (included) | |
Temperature Probe |
HI 7662-T stainless steel temperature probe with 1 m (3.3’) cable (included) | |
Logging | Record | 100 lots with 10,000 record/lot |
Interval | settable between one and max log time | |
Type | automatic, log on demand, AutoHold | |
Replatinization | yes | |
Display | 240 x 320 dot-matrix color LCD with on-screen help, graphing, language selection and custom configuration | |
PC Connection | RS232, USB | |
Power Supply | 12 VDC adapter (included) | |
Environment | 0-50ºC (32 to 122ºF) (273 to 323K) RH max 95% non-condensing | |
Dimensions | 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”) | |
Weight | 1.2 Kg (2.6 lbs.) |
Hanna EC 215 Mutti Range
This instrument utilizes a four ring potentiometric probe with platinum sensor that offers greater versatility over typical amperometric designs. A potentiometric probe works on the principal of induction which eliminates the effects of polarization (a common problem of amperometric systems). Two outer rings apply
The Hanna EC215 is a multi-range bench top conductivity meter with four measurement ranges to ensure the highest resolution and accuracy to meet your measuring requirements.
Calibration is performed manually using 1-point simply by adjusting a knob on the front of the meter. With a user selectable temperature coefficient and a temperature sensor incorporated in the probe, temperature compensation of the reading is automatic.
Included with this meter is the fast responding HI 76303 probe. This probe is equipped with a 4-ring platinum sensor, built-in internal temperature sensor and a 1 m long cable, which can be used for measuring highly acidic or alkaline samples.
The EC215 is supplied complete with HI 76303 probe with internal temperature sensor and 1m long cable, 12 Vdc adapter and instructions.
OAKTON CON2700 Benchtop Meter
CON 700 meter reads 0 to 200 mS across five ranges—autoranging feature automatically gives the best resolution for your measurements. Calibrate at up to five conductivity points (one per range) for improved measurement accuracy. Adjustable temperature coefficient provides additional accuracy.
Brilliant backlit display with dynamic stability indication
Up to 500 point memory with date-time stamp for GLP
Output data to printer or PC
Accepts either 2-cell or 4-cell electrodes
Features auto-standardization, auto-calibration, and autoranging
Calibration due alarm with password protection for setup and calibration
Measures salinity from 0.0 to 80 ppt and resistitivy from 2.000 ohms to 20.0 Mohms
The CON 2700 meter offers a new compact design that is over 40% smaller than other benchtop meters. The large display is easy to read even at a distance and features stability indication. All measurements include temperature display. The meter includes automatic or manual temperature compensation, temperature in °F or °C, and display Hold. A calibration due alarm function means no more out-dated calibrations. The water-resistant membrane keypad offers password protection for both set-up and calibration.
Multiple pH slopes and offset display enables quick, easy electrode diagnosis. The electrode holder can be mounted on either side of the meter. The convenient pull-out, quick-reference card keeps keypad functions at your fingertips.
]]>Besides custom dual-display LCD, the CyberScan Standard and Waterproof series feature handy electrode holders for easy one-hand operation and built-in meter stands for table top measurements.
Other features include AC adaptor, builtin memory of up to 100 data sets for selected
Conductivity meters, CyberScan CON 400 / 03K Portable and watertight. Individually adjustable with selectable temperature correction value and ambient temperature. A further development of the traditional portable meter. Completely water and dust proof in accordance with IP 67.
Product Features
:: | Waterproof and dustproof to IP67 |
:: | Deliver lab-accurate results stamped with time and date for GLP-compliant research |
:: | Conveniently auto-ranging with up to 5-point push button calibration |
:: | Selectable cell constant |
:: | GLP-compliant |
:: | Selectable automatic/manual temperature compensation |
:: | Hold function freezes readings for easy reference |
:: | Auto-off conserves energy and lengthens battery life-span |
:: | Non-volatile memory holds up to 50 data sets even when you run out of batteries |
:: | Ergonomic design for that perfect palm fit. Rubber grips at either side of the meter for firmer grip |
:: | Conductivity electrode with built-in ATC and minimal bubble entrapment design |
:: | Available in complete kit version |
Range | 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm |
|
Resolution | 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm |
|
Accuracy @ 20°C | ±1% F.S. (excluding probe error) | |
Calibration | manual, one point | |
Temperature Compensation |
automatic, 0 to 50°C (32 to 122°F) with ß adjustable from 0 to 2.5%/°C | |
Probe | HI 76302W four ring conductivity probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable (included) | |
Battery Type / Life | 9V / approximately 100 hours of continuous use | |
Environment | 0 to 50°C (32 to 122°F); RH max 100% | |
Dimensions | 145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’) | |
Weight | 230 g (8.1 oz.) |
Condition